![]() ![]() If Recipe Manager is started using the path Start Program Wonderware InTouch Recipe, then select Run as Administrator on Windows Vista or later operating systems. Wonderware InTouch HMI 10.6 does not support the following functions on these operating systems: WWPoke, WWExecute, WWRequest, ActivateApp and SendKeys. Refer to the updated Tech Note 725, 'Running InTouch HMI and AlarmDBLogger Services on Vista and Later Operating Systems,' for full details of the supported scenarios and applicable alarm query syntax. Also, if you are running the Alarm DB Logger as a console application, you cannot run it in the Terminal session until you close the one that is running in as a console application. If InTouch HMI needs to run in the Console session, the Alarm DB Logger must be configured in the Alarm DB Logger Manager as a 'Normal Application' instead of a 'Windows Service'. However, there is a limitation in that the combination of Alarm DB Logger configured as a service and InTouch HMI running locally as a console application is still not supported. The Alarm DB Logger now runs as a Service in Windows Vista and later operating systems primarily to support Galaxy Alarms and InTouch HMI Alarms from Terminal sessions. In earlier releases that supported Windows Vista, Windows 7, or Windows Server 2008, the Alarm DB Logger could not be enabled to run as a service. Test to validate that the alarms generated from the alarm-providing node are shown accurately in the AlarmViewer control.